Troubleshooting
Run sudo /opt/pilens/diagnose.sh first — it bundles logs and state with
secrets redacted. Then:
| Symptom | Check | Fix |
|---|---|---|
| Web UI won't load | systemctl status pilens; is your source IP in the management subnet? |
sudo /opt/pilens/repair.sh; widen the subnet from the console if locked out (see operations.md) |
| Browser certificate warning | Expected (self-signed). Compare the fingerprint the installer printed. | Trust it for this host, or import /var/lib/pilens/tls/mgmt.crt |
| Can't log in | — | sudo -u pilens /opt/pilens/bin/pilens reset-password -user admin |
Locked out by 429 |
Login throttling after failures | Wait the stated time, or restart pilens to clear the limiter |
| No clients get an address | systemctl status pilens-dnsmasq; another DHCP server on the AP link? |
repair.sh; ensure no stray dnsmasq/hostapd is running |
| AP won't start | journalctl -u NetworkManager; radio AP-mode and band/country support |
Try WPA2 / 2.4 GHz / a permitted channel; failed applies roll back automatically |
| Clients associate but no internet | Dashboard "forwarding" card; Ethernet default route up? | Check the uplink; forwarding must read "forwarding", not "blocked" |
| Capture shows drops | System Health / Findings; CPU or SD-card bound | Use a capture filter; capture to an SSD (operations.md) |
| "interrupted" sessions after power loss | Expected: segments are hashed and re-indexed on restart | Verify hashes in Capture Library → Integrity |
| High CPU / slow filters | Large capture; tshark re-reads segments | Filter narrows after the first run (cached); smaller segment size helps |
| Under-voltage warning on dashboard | rpi_volt alarm |
Use the official PSU; under-voltage corrupts storage and drops packets |
If a network change ever leaves the appliance unreachable, every apply keeps a backup and rolls back on failure; the last-known-good firewall is also restored at boot before the AP starts.